installing B3782XSW and B3782IPR patch bundles
1. Login as root.
2. Downloaded the appropriate patch bundle to /tmp.
3. Verify that the file has downloaded correctly using swlist. For
example, to verify the XSW700GR1020 bundle, enter:
swlist -d @ /tmp/XSW700GR1020_10.20_700.depot
# Initializing...
# Contacting target localhost...
#
# Target: localhost:/tmp/XSW700GR1020_10.20_700.depot
#
#
# Bundle(s):
#
XSW700GR1020 B.10.20.46 General Release Patches for HP-UX 10.20 Workstations
4. Back up your system.
5. Use swinstall to install the patches. Be sure to select the SD
matching operation appropriate to the release. For example, to install
the HP-UX 10.20 general release bundle on a Series 700 (workstation)
system, enter:
swinstall -s /tmp/XSW700GR1020_10.20_700.depot
-x autoreboot=true -x match_target=true
Note: Your system will reboot after the bundle is installed.
Rev: 12Feb01
|