1 ANTENNA SET\ANTENNA Iant ON Station TO Correlator_Entry Define position of antenna Iant and associated correlator entry. This command is available only in CONFIGURE mode, selected using SET MODE CONFIGURE command. After configuration has been specified, observations can be resumed using the OBSERVE command. 1 CABLE SET\CABLE Irec Reset phasemeter counter for specified receiver. 1 DELAY SET\DELAY Del/ANTENNA Iant Specify the delay offset (in nanoseconds) of antenna Iant. The Station.Antenna file is updated. The delay can be determined using the CLIC\SOLVE DELAY command, which produces a file containing the appropriate SET\DELAY commands. 1 OBSERVE SET\OBSERVE This command send all configuration parameters to the shared commons, and reload the Station.Antenna files. It turns off the SET\ language, and activates the OBS\ language to allow observing. Note that all temporary changed specified by OBS\CORRECTIONS command are overwritten. 1 PHASE SET\PHASE LO1|LO3 Phase /ANTENNA Iant /RECEIVER irec Define the LO1 and LO3 phases of the specified receiver and antenna. LO3 phases allow to recenter the phases of the USB and LSB to the same value, and LO1 phases allow to set this value to zero. Appropriate values are computed by CLIC command SOLVE GAIN. 1 POINTING SET\POINTING [IAZ Value] [IEL Value] [DVE Value] [DVN Value] [IVE Value] [IVN Value] /ANTENNA Iant Specify new (station dependent) pointing constants for antenna Iant. The Station.Antenna file is updated. IAZ is the zero of azimuth, IEL of elevation, IVE and IVN the inclinations from the inclinometers, DVE and DVN offset from these inclinations. IVE and IVN are normally determined by the INCLINOMETER procedure, while DVE and DVN should be zero. Values can be arithmetic expressions, e.g. as in command SET\POINTING IEL IEL-6 IAZ IAZ+15/ANT 3 1 RESTART [SET\]RESTART [Program] Restart a program. The program can be RDI, CORREL or AFF. This command is typically used after a OBS\CANCEL STOP command, or when the program died of unnatural causes (crash...). By default, RESTART waits for end of observation. In case of abnomalous death of RDI or CORREL, this may never happen. Pressing C interrupts the wait state in this case. If OBS stills wait for start of scan, you may have to type a CANCEL WAIT command to be able to restart. 1 SHOW SET\SHOW Item Show some configuration parameters SET\SHOW ANTENNA Iant will list the Station.Antenna file, giving pointing constants, position from station, and zero delay. It is equivalent to the command SIC\TYPE INTER_BASE:Station.Antenna except for an automatic determination of the file name. SET\SHOW ARRAY shows the current array configuration. 1 SINGLE SET\SINGLE Isin Define the single-dish antenna, i.e. the antenna connected to the precision detector. 1 XYZ SET\XYZ dX dY dZ/ANTENNA Iant Specify position (difference from station coordinates) of antenna Iant. The Station.Antenna file is updated. dX dY dZ can be measured by a baseline calibration, and using the CLIC\SOLVE BASELINE command in CLIC, which will create a procedure containing the appropriate SET\XYZ commands for all antennas. dX dY dZ are in meters. 1 END