1 Description ------------------------------------------------------------------------------- Display package for 2-receiver data S. Guilloteau 30-Apr-1997 ------------------------------------------------------------------------------- This is an X-window interface for command procedure to display a visual summary of basic information (Tsys, Water, scan lists, etc...) for dual-frequency observations. The procedure works also for 1 receiver only. Active Buttons: --------------- GO Perform all steps in sequence. LIST Select and list observations; Must be done after FILE is changed. TOTAL Plot total power output of receivers TSYS Plot system temperature of receivers WATER Plot derived water vapor content of the atmosphere PRINT Prepare report: show-file_name.ps, a Postscript file including plots. Inputs: ------- 2 DO_TEX "Produce TeX report ?" Produce an illustrated Postscript log file (file_name.ps) of the calibration process. The ascii summary file (file_name.sum) is produced in all cases. 2 IREC "Receiver numbers ?" e.g. "1 2" for both, "1 0" for 1 only, "2 0" for rec. 2 only; if both, use rec. 1 phase for rec. 2 2 FILE_NAME "File name ?" Press FILE for browser. 2 SCAN_RANGE "Scan range ?" First and Last scan to be used. Set FIRST = 0 and LAST = 10000 for all scans (the default). 2 MIN_QUAL "Minimum quality ?" Minimum data quality required for data selection. 1 END