% @(#)save_ccd.hlq 17.1.1.1 (ESO-IPG) 01/25/02 17:48:54 %++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ %.COPYRIGHT (c) 1993 European Southern Observatory %.IDENT save_ccd.hlq %.AUTHOR Rein H. Warmels, IPG/ESO %.KEYWORDS MIDAS, help files, SAVE/CCD %.PURPOSE On-line help file for the command: SAVE/CCD %.VERSION 920602 RHW Created %.VERSION 930325 RHW minor modification %.VERSION 931101 RHW Released %---------------------------------------------------------------- \se SECTION./CCD \es\co SAVE/CCD 1-Nov-93 RHW \oc\su SAVE/CCD name save current CCD session \us\pu Purpose: Save the current CCD keywords and control table into a session table. \up\sy Syntax: SAVE/CCD name \ys\pa name = session name; no default \ap\no Note: The command will save the CCD keywords as well as the CCD reduction table into a table called P1_REDUC.tbl, where P1 is the session name you gave as input. In case the reduction table doesn't exist an empty table will be created. \\ The command `INIT/CCD name' can be used to restore the session status. \on\see See also: INIT/CCD, LOAD/CCD \ees\exs Examples: \ex SAVE/CCD mysession Save the CCD keyword structure and and the reduction table stored in the table mysession_REDUC. If no reduction CCD table exists only the CCD keyword settings will be saved in that table. \xe \sxe